Commercial kitchen equipment for Australian hospitality

Expert advice · Australia-wide delivery


Menu

User manual

Borrelli1 Door Stainless Steel Bar FridgeUser Manual

BC-130-SS / BC-130-SS-DX

Installation, cleaning, controller settings and troubleshooting for the stainless steel models.

Looking for BC-130 / BC-130B?

01Warnings and Safety

  • Keep all ventilation openings clear during operation. Do not use mechanical devices or other means to accelerate defrosting.
  • Do not use electrical appliances inside the storage compartment.
  • Use a dedicated wall outlet. Disconnect the power supply before cleaning, maintenance or replacing parts.
  • Do not damage, modify or excessively bend the power cord. A damaged cord must be replaced by a qualified technician.
  • LED replacement, repairs, disassembly and modifications must be performed by a qualified person.
  • Do not store explosive substances, including aerosol cans with flammable propellant. Do not use flammable sprays or substances near the appliance.
  • This fridge is intended for storage and display of beverages. Do not use it for other purposes.
  • Do not insert fingers, sticks or other objects into the cold-air suction outlet.
  • Do not place heavy objects or containers of liquid on top of the unit.
  • Dispose of the appliance through an authorised waste centre. Do not expose it to flames.

Expected operating noise level: up to 55 dB.

02Installation

Before use

  1. Remove transport packaging and leave the door open to ventilate.
  2. Clean the appliance before use.
  3. Run the unit for one hour to cool the compartment before loading beverages.

Position and operating environment

  • Install on a flat, stable surface that can safely support the loaded appliance.
  • Keep out of direct sunlight, rain and weather. Use a temperature-controlled indoor environment.
  • Do not install where the ambient temperature exceeds 32 °C.

03Cleaning

Exterior and interior

  • Use a dry cloth to remove dust from inside and outside the cabinet.
  • For a deeper clean, use an appropriate detergent and a soft cloth.
  • Do not use polishing powder, soap powder, benzine, oil or hot water. These can damage paint and plastic parts.

Condenser maintenance

Every few months

The condenser is located behind an access cover at the rear of the fridge. Switch off and unplug the unit before carefully removing the cover, then clear dust and debris from the condenser with a soft brush.

Clean it every few months, or more often in dusty or high-use environments. Refit the access cover securely when finished.

04How to Use

These instructions apply to BC-130-SS and BC-130-SS-DX. Use the SET, arrow and snowflake buttons on the fitted controller.

Change the set temperature

  1. Press and hold SET until the temperature setting flashes (approximately two seconds), then release.
  2. Use the arrow buttons to adjust the setting. Recommended setting: 2.5 to 3 °C.
  3. Press SET to save.
  4. The controller returns to displaying the current cabinet temperature.

Change the temperature differential

The supplied manual calls this the variance setting (rd). It is separate from the desired cabinet temperature.

  1. Hold SET until P5 flashes (approximately seven seconds), then release.
  2. Press DOWN once to select rd, then press SET to view the flashing value.
  3. Use the arrow buttons to adjust the value. Recommended setting: 3 to 5 °C. Press SET to save.
  4. When rd flashes again, hold SET for approximately five seconds to return to the main display.

Manual defrost

  1. Hold the snowflake button for approximately three seconds, then release.
  2. The snowflake indicator illuminates when defrost begins.
  3. The indicator switches off automatically when defrost is complete.

05Tips and Tricks

Transportation

  • The unit may be transported on the back for short periods.
  • After transport, leave the unit standing upright for 12 hours before switching on.
  • Protect the power cord during transportation.

Drain tray

Defrost is automatic. Water collects in the drain tray and evaporates automatically.

Shelves and airflow

  • Adjust shelves to suit the items stored. Maximum load is 25 kg per shelf.
  • Do not obstruct the fan with stock. Keep the air inlet and suction outlet clear.

Condensation

Condensation can occur in humid conditions. Wipe it away with a damp cloth. This is normal in humid conditions.

Ambient temperature

Use indoors in a temperature-controlled environment with an ambient temperature no higher than 32 °C.

06Before Requesting Service

ProblemChecks
No refrigerationIs the power supply interrupted? Is the power cord connected securely? Has a fuse blown or a circuit breaker tripped?
Inadequate refrigerationIs the temperature setting appropriate? Are the air inlet or suction outlet obstructed? Is stock packed too tightly? Is the door opened frequently or left ajar?
Excessive noiseAre all feet firmly on the floor? Is the back touching a wall or another object? Are objects resting against the back?

Enquiries

If the problem continues, contact Borrelli. Have the model and serial number ready.
Phone: 03 9783 6325
Email: [email protected]
Website: www.borrelli.com.au